DoesTheMath

A. O. SMITH T-H3M-OS-N 1**

0.91 UEF DOE CCD · 2026-09-19
C

Grade C: where this UEF sits among the 80 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking this unit's figures, A. O. SMITH T-H3M-OS-N 1**, a gas tankless unit, uses 122 therms of natural gas a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 13 therms below the class median of 135 therms across 80 models.


Energy use per year

122 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is below the median of 135 therms for the 80 models registered in the same heater type and draw pattern; it ranks 4 of 80, lowest energy first.

This model: 122 therms

Solid line: this model (122 therms). Dashed line: the class median.

Min 114 therms Median 135 therms Max 137 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.91 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
3.5 gal/min DOE CCD · 2026-09-19

What it costs to install

$2,169–$3,184 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 122 therms figure applies to natural gas at the medium draw pattern only, a typical three- or four-person household using hot water on a busy morning. It is not a value measured in the registry. This site computed it from the registry's UEF, the ratio of hot water delivered to energy used, and the DOE test's daily hot-water draw for that pattern. The registry lists a UEF of 0.91 for T-H3M-OS-N 1**. The energy source is DOE CCD, retrieved 2026-09-19. A household with a different daily draw would have a different annual figure, and this page has no values for the other draw patterns.

Among the 80 models registered as a gas tankless unit at the medium draw pattern, this unit ranks 4th lowest of 80 for energy use. That places it in the lowest quarter of its class, at 122 therms against a class median of 135 therms. The gap is 13 therms a year at the same draw pattern. The comparison suits a household whose use resembles the medium pattern and who wants to check a listed figure against its class. It suits less well a household whose hot-water use is much heavier or lighter than the test draw. The registry lists a maximum flow rate in gallons per minute of 3.5. The conditions behind that rating are not available here, so this page cannot say how the unit performs with several fixtures running.

Running cost is not written in this text because it depends on the state average residential gas price, which differs by reader. The cost calculator applies that price to the 122 therms for T-H3M-OS-N 1** once you enter your ZIP. The steps behind that calculation are described in how the annual cost is calculated. The modeled installed-cost range appears in its own block with its source and date, and it is a modeled range, not a quote. To compare this unit with another in the same class, find a same-class replacement by model number and read its energy at the medium draw pattern. A comparison across different draw patterns would not use the same daily draw.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.91 · Grade C Price it on your ZIP