DoesTheMath

A. O. SMITH HPTU-80N 1**

3.45 UEF DOE CCD · 2026-09-19
C

Grade C: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

Checking A. O. SMITH HPTU-80N 1**, an electric tank? At the high draw pattern, the standard daily hot-water usage DOE tests against, it uses 1,438 kWh of electricity a year. That is 132 kWh above the 1,306 kWh median of 194 comparable models, and it is 135th lowest energy use of that group.


Energy use per year

1,438 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 135 of 194, lowest energy first.

This model: 1,438 kWh

Solid line: this model (1,438 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.45 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
86 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
82 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2019-04-05 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's rated tank size lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers45°F min
  • Physical footprintEnter your numbers27" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The figure of 1,438 kWh is calculated by this site, not published by the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, which is 3.45 for this model, with the daily hot-water draw that the DOE test sets for the high draw pattern. The source is the DOE CCD, retrieved 2026-09-19. The figure holds only at that test draw, so a home that uses more or less hot water will see a different total. Against the class median of 1,306 kWh, this model sits 132 kWh higher. That places it in the second-highest quarter of its class for energy use, at 135th lowest of 194. The method for the annual calculation is documented separately.

The high draw pattern describes a larger household, or one where showers and laundry overlap. For this model, the first hour rating, the gallons of hot water available in the first hour from a full tank, is 86 gallons, and the rated volume is 82 gallons. The energy figure applies to households whose use matches that pattern. It does not describe a smaller household with a lower daily draw, and this page gives no energy figure for other draw patterns. It also says nothing about a specific home, because the calculation uses the test draw and not a metered result. Readers comparing other sizes or fuels can use the selector by fuel, space and size.

Running cost is not stated here because it depends on the reader's own utility electricity tariff. The cost calculator applies the rate for your ZIP to the 1,438 kWh at the high draw pattern. No installed price range is published for this model. Its ratings, 86 gallons first hour rating and 82 gallons rated volume, lie outside the range the cost database's model was fitted on, and that range is not stretched past its limit. The registry data used here does not say whether this model is priced above or below others in its class. To compare against another unit of the same class, find a same-class replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going